ANNJET special multi-enzyme cleaning solution for endoscopes
Main active ingredients:Protease, lipase, cellulase, pectinase and other biological composite enzymes, stabilizers
Scope of use:Suitable for hand washing and machine washing of all kinds of soft and hard endoscopes
Method of use:
Reference dilution ratio: hand washing ratio is 1:300~1:400, machine washing ratio is 1:400, cleaning temperature: 20 ℃-45 ℃, the higher the temperature within this range, the better the cleaning effect, and the recommended temperature is 40 ℃.
1. Disassemble the instrument to a small unit after use, clean the outside first, and then inject the cleaning liquid into the inside of the pipeline. All endoscope accessories, various buttons, valves, etc. shall be put into the diluted cleaning liquid, soak for at least 2 minutes, flush the multi-enzyme cleaning liquid with clear water, and use a special soft brush to help clean when necessary;
2. The multi-enzyme cleaning solution should be replaced after washing the endoscope once. The equipment that needs to be disinfected with aldehydes should be washed first and then eliminated, that is, after cleaning with this product, rinse with water, and then put into aldehyde disinfectant after drying to soak in order to prevent protein aldehyde denaturation, resulting in solidification and bonding;
3, the use of ultrasonic cleaning need to add enzyme cleaning 2-10 minutes;
4. Please adjust the dilution ratio and soaking time according to the degree of pollution and the load.
Specifications:600ml/bottle, 2.5L/barrel, 5.0L/bottle
Performance characteristics:
1. This product is designed for endoscopic cleaning, contains a variety of biological enzymes and active substances, can quickly decompose bile, blood, fat and other pollutants, enhance the cleaning effect;
2. Cleaning faster, more effective, with the ability to enter the complex small cavity;
3. Quickly penetrate into the biofilm, peel and decompose the biofilm, completely remove and inhibit the formation of biofilm, and ensure the effectiveness of sterilization;
4. No bubble products, easy to rinse no residue, significantly improve the turnover speed of endoscopy and surgical instruments;
5. The pH value is neutral, non-corrosive to the endoscope material, and can effectively inhibit the atomization of the endoscope.
- Product Description
-
Main active ingredients:Protease, lipase, cellulase, pectinase and other biological composite enzymes, stabilizers
Scope of use:Suitable for hand washing and machine washing of all kinds of soft and hard endoscopes
Method of use:
Reference dilution ratio: hand washing ratio is 1:300~1:400, machine washing ratio is 1:400, cleaning temperature: 20 ℃-45 ℃, the higher the temperature within this range, the better the cleaning effect, and the recommended temperature is 40 ℃.
1. Disassemble the instrument to a small unit after use, clean the outside first, and then inject the cleaning liquid into the inside of the pipeline. All endoscope accessories, various buttons, valves, etc. shall be put into the diluted cleaning liquid, soak for at least 2 minutes, flush the multi-enzyme cleaning liquid with clear water, and use a special soft brush to help clean when necessary;
2. The multi-enzyme cleaning solution should be replaced after washing the endoscope once. The equipment that needs to be disinfected with aldehydes should be washed first and then eliminated, that is, after cleaning with this product, rinse with water, and then put into aldehyde disinfectant after drying to soak in order to prevent protein aldehyde denaturation, resulting in solidification and bonding;
3, the use of ultrasonic cleaning need to add enzyme cleaning 2-10 minutes;
4. Please adjust the dilution ratio and soaking time according to the degree of pollution and the load.Specifications:600ml/bottle, 2.5L/barrel, 5.0L/bottle
Performance characteristics:
1. This product is designed for endoscopic cleaning, contains a variety of biological enzymes and active substances, can quickly decompose bile, blood, fat and other pollutants, enhance the cleaning effect;
2. Cleaning faster, more effective, with the ability to enter the complex small cavity;
3. Quickly penetrate into the biofilm, peel and decompose the biofilm, completely remove and inhibit the formation of biofilm, and ensure the effectiveness of sterilization;
4. No bubble products, easy to rinse no residue, significantly improve the turnover speed of endoscopy and surgical instruments;
5. The pH value is neutral, non-corrosive to the endoscope material, and can effectively inhibit the atomization of the endoscope.