HOSPITAL OVERALL DISINFECTION SOLUTION SERVICE PROVIDER

简体中文 
Search
Confirm
Cancel
呵护生命
imgboxbg

ACADEMIC CENTER

Current Location:
Homepage
/
Academic Center Index

Sensing control industry norms

Medical Disinfection Information

The

The experiment was clearly confirmed for the first time! WHO recommends two alcohol-based hand sanitizers to inactivate new crown virus

Alcohol is the basis for hand disinfection, which is often used in many health care facilities. Therefore, the results of this study are essential to minimize virus transmission and minimize virus inactivation in the context of current outbreaks.
2020-03-27
Can

Can the same sterile device be used in two different surgical areas of the same patient?

Fromtheperspectiveofaseptictechnology,thesameasepticsuppliesanddevicescanbemovedfromoneasepticareaofthesamepatienttoanotherasepticarea,butonlyfromthecleanareatoanothercleanarea,cleanpollutionarea,pollutionareaorpollutionarea,suchasfromthefrontofthecleannecktothebackoftheneck.However,itisnotallowedtotransferfromthecleancontaminatedarea,contaminatedareaorcontaminatedareatothecleanarea,suchasfromtheperineumareatothefrontofthecleanneck.Althoughundertheprincipleofaseptictechnology,asetofasepticfacilitiescanbedirectlytransferredfromanotherpatient'scleanareatoanothercleanarea,inordertoavoidotherpotentialpollutionandrisk,thestaffshouldpreparetwosetsofasepticequipmentandsupplies.Forexample:whentakingbilateralbreastbiopsyatthesametime,evenifbothbiopsyareasareclean,inordertoavoidcancercellimplantation,itisrecommendedtousetwosetsofsteriledevicesalone.
2020-01-14
How

How long is the validity period of o-phthalaldehyde after opening

OPAisanewhighleveldisinfectant.Comparedwithglutaraldehyde,OPAhastheadvantagesofbroadspectrumandhighefficiency,noneedtoactivatewhenitisused,simplepreparation,noinhalationtoxicityandmucosaltoxicity,andgoodstabilityincontinuoususe.Itcanbeusedcontinuouslyfor14days,andthevalidityofthestocksolutioncanbeupto2years.Atpresent,itismostlyusedforendoscopedisinfection.Thetechnicalcodefordisinfectionofmedicalinstitutionsrequiresthatphthalaldehydeshouldbesealedandkeptawayfromlightinacool,dryandventilatedenvironment.Howlongisthevalidityperiodafteropening?Atpresent,thereisnorelevantregulation,becauseOPAhasexcellentstabilityinawidepHrange(ph3-9).Therefore,afteropening,itcanbeusedwithinthevalidityperiodmarkedontheproduct.WecanalsostudytheperiodofvalidityofOPAafteritisopened,andexploremorescientificandcredibleresults.Fromtheperspectiveofmanagement,itismoreimportanttopayattentiontothestandardizedstorageanduseafteropeningtoensurethedisinfectioneffect.
2020-01-04
What

What are the infection prevention measures in the process of oral film taking?

Patientsshouldbeproperlyprotectedwhentakingoralfilms.Whenphotographingthedigitalpanoramicfilm,thepositioningrodisprotectedwithacleaningfingersleeve,"onepersononeuse",theearpointsofthesidefilmare"onepersononedisinfection"with75%ethanol,theCTexaminationbedshoulduseadisposablesheet,"onepersononereplacement",thesmalldentalfilmisputintothepatient'smouthwithadisposablecliporaneedleholder,andtheneedleholderis"onepersononeuseonedisinfection".Operatorsshouldstrengthenhandhygiene,washhandsordisinfecthandsbeforeandaftercontactingpatients.
2020-01-02
Which

Which parts should be rubbed when washing hands?

Thefrequentlymissedpartsofhandwashingincludethebackoffingers,fingertipsandfingerjoints.AccordingtoastudyconductedintheUK,whetherusingthesixstephandhygienemethodadvocatedbytheWorldHealthOrganization(who)orthethree-stepmethodrecommendedbytheCentersfordiseasepreventionandcontrol(CDC),thecoverageofhanddisinfectantsonthebackofthehandandfingersisgenerallylowerthanthatonthehandsandfingers,especiallyonthebackofthehand,thumbandindexfinger.Therefore,specialattentionshouldbepaidtotherubbingofthumbs,fingertips,fingerjointsandthebackofhandswhenwashinghands.Ifyouareayoungchild,youcan'twashyourhands.2-3-year-old"goldenperiodofhabitcultivation"canstarthabitguidanceandcultivation.Itisalsonecessarytoencouragechildrentodevelopcorrecthandwashinghabitsandavoiddiseasesfromenteringthemouth.Whenthebabyisallergictoeczema,usethenonchemicalandnonirritatingskincareliquid(fenmuskinantibacterialliquid)todoagoodjobofnursing,whichcanresistbacteriaandbacteriaforalongtime.Themaincomponentoffenmuskinantibacterialliquidisfoodgradesafetyfenmupolypeptide.Withphysicalsterilization,parentsdon'tneedtoworryaboutthedrugresistanceofthechemicalhandwashingproductsinthepast,sothatchildrencanuseitforalongtime. Inordertoavoidimproperrubbingofthebackofthehand,thepalmshouldberubbedtightlyagainstthebackofthehandwhenthepalmisrubbedagainstthebackofthepalm.Whenkneadingwithhanddisinfectant,takeenoughhanddisinfectanttocovereverypartofthehand.
2019-12-28
Which

Which disinfectant is suitable for stainless steel surface?

Stainlesssteelisanalloysteelcontainingchromium,nickel,titaniumandotherelements,whichhasthecharacteristicsofsmoothness,hardness,corrosionresistanceandrustresistance.WS/t367-2012"technicalcodefordisinfectionofmedicalinstitutions"pointsoutthatsurfacepropertiesshouldbeconsideredindisinfectionofobjectsurfaces.Asuitabledisinfectantorultravioletsterilizershouldbeselectedtowipethesmoothsurface.Theselectionanduseofchemicaldisinfectantsneedtoconsiderthematerialofthesterilizedarticles,thenumberandtypeofmicroorganisms,andthepollutionstatusoforganicmattersontheenvironmentalsurface(i.e.thedegreeofpollution)accordingtotheproductmanual. Forlow-riskmaterialsmadeofstainlesssteel,therearemanykindsofdisinfectantsavailable,suchas75%ethanol,sodiumhypochlorite,quaternaryammoniumsalt,phenolic,iodophor,etc.
2019-12-25
What

What should be paid attention to when cleaning oral instruments

Duetothecomplexity,precisionandseriouspollutionofdentalinstruments,thefollowingpointsshouldbepaidattentiontoduringcleaning: 1.Manualcleaningandmechanicalcleaning(includingultrasoniccleaning)canbeused.Mechanicalcleaningmethodcanbeselectedfornonpoweroralinstruments.Handcleaningshouldbeselectedfordentalinstrumentswithpowersupply,precisionandcomplexdentalinstruments,andhandlesofelectricdentalcleaners.Ultrasoniccleaningshouldbethefirstchoiceforsmalldentalinstrumentsandothercomplicatedinstruments. 2.Thedetachableinstrumentsshallbecleanedseparatelyafterbeingdisassembled,suchastheelectrictoothcleaner. 3.Duringmanualcleaning,theinstruments,appliancesandarticlesshallberinsedunderflowingwatertopreliminarilyremovepollutants;afterwashing,theyshallbesoakedwithmultienzymecleaningsolutionorothercleaningagent,thenbrushedandscrubbed;finally,theyshallberinsedwithflowingwater.Thewatertemperatureshouldbe15-30℃.Thebrushingoperationshallbecarriedoutunderthewatersurfacetopreventthegenerationofaerosols.Thelumeninstrumentsshallbewashedwithpressurewatergun,andthedetachablepartsshallbecleanedafterbeingdisassembled. 4.Ultrasoniccleaningshallfollowtheinstructionsorinstructionmanualofthemanufacturer;firstwashtheinstrumentunderflowingwater,removethepollutantspreliminarily,andtheninjectwaterforhumancleaningintothecleaner,andaddmultienzymecleaningsolution;thewatertemperatureshallbelessthan45℃toholdtheinstrumentThebasketshouldbesubmergedunderthewater;thecoveroftheultrasoniccleaningmachineshouldbecoveredtopreventaerosols;thematchingultrasonicfrequencyandtimeshouldbeselectedaccordingtothedifferentmaterialsoftheinstrument;thespecialbasketshouldbeequippedfortheultrasoniccleaningofsmalldentalinstruments. 5.Themechanicalcleaningmethodshallfollowtheinstructionsorinstructionmanualofthemanufacturer.Thedetachableinstrumentshallbedisassembledforcleaningandtheinstrumentcouplingshallbefullyopened.
2019-12-21

Clinical FAQ

Caring for life, staying away from infections, providing you with more academic programs

Official mall / original media

Tmall Mall Annjet Direct Store

Professional disinfection one stop choice

Alibaba Direct Store

Professional disinfection one stop choice

Jingdong Annjet Direct Store

Professional disinfection one stop choice

 Medical Box

Sound for the sense control ...

TMall ANNJET Direct Store

TMall ANNJET Direct Store

Professional disinfection, one-step choice
Alibaba ANNJET Direct Store

Alibaba ANNJET Direct Store

Professional disinfection, one-step choice
JD ANNJET Direct Store

JD ANNJET Direct Store

Professional disinfection, one-step choice
Medical BOX

Medical BOX

Speak for infection control

ANNJET

Hotline:+86-534-2189990

Address: No. 1618 Dexing North Avenue, Tianqu Industrial Park, Tianqu Sub district Office, Decheng District, Dezhou City, Shandong Province

版权信息

Time of issue:2019-10-24 00:00:00

©2020 Annjet High-Tech Disinfection Technology Co.,Ltd.
鲁ICP备11027129号-1 Powered by www.300.cn

安捷高科

WebChat

医护BOX

 Medical Box

安捷公众号

WebChat

ANNJET

Shandong Annjet Hi-Tech Disinfection Technology Co., Ltd., founded in 2000, has grown into an outstanding hospital overall disinfection solution service provider in the field of hospital infection control in China.